JSM 300 DL METAL ROOF SYSTEM
3" STRUCTURAL STANDING SEAM PANELS
Overview
Specs & Dimensions
Install & Retrofit
Downloads
JSM 300 DL standing seam panels are perfect for installation over open frame or solid deck where the advantages of a taller seam or wider panel can be utilized. Site forming continuous length panels onto the roof using one of our Archzilla® trucks makes this system ideal for new construction or re-roof applications directly over existing metal roofs, single ply or modified roofs down to slopes of ¼:12.
Low slope standing seam or lap seam metal roofs fail at the end laps. Metal roof panel end laps are bad no matter what the slope, but on a low slope they provide a situation for water damming, then panel failure.
Our Roof Panels Resolve problems that occur with Standard Metal Roof Installations:
-
NO Vulnerable End Laps
JSM 300 DL panels have no end laps because they are manufactured right onto the roof
-
NO Exposed Fasteners
ABC's Metal Roof Panels have no exposed Fasteners
-
NO Flashing Problems
Our JSM 300 DL Panels have vertical ribs, so flashing is a breeze
JSM 300 DL panels have no end laps because they are manufactured right onto the roof in lengths up to 250 feet using one of our Archzilla® jobsite production monster trucks. The JSM 300 DL standing seam panel is available in both 16” and 22” widths. A vertical rib makes flashing a breeze.
JSM 300 DL (double lock)
- Bold 3" tall seam
- Perfect for low slopes, open frame, and retrofit
- Superior water-tightness
- Jobsite Production capabilities for long panels
- Oil-can-reducing striations or stiffener ribs available
- Minimum slope ¼:12
The system features a 3 inch tall vertical rib standing seam panel that is seamed on the roof after installation. The panels are held to the substrate using 6 inch long, 20 gauge clips that allow for a full 2.5 inches of thermal movement.
Standard Widths - 16" & 22"
Applications for the JSM 300 DL Roof System
Structural Panel used on Roof Slopes 1/2:12 or greater. Continuous lengths, up to 250 ft.
- Open Purlin
- Re-Roof Over Existing, Modified, Built-up or Single-Ply
- Retro-Z
- Plywood
- Metal Deck
- UL 580 Class 90 Uplift
- UL 1897 Uplift
- ASTM E-1592 Uplift
- UL Class 4 Impact Resistance
- UL Class A Fire Rating
24 Gauge, 22 Gauge
Alum-Zinc Coated Steel
Acrylic-Coated Galvalume and Fluoropolymer
(Kynar® 500 PVDF resin-based)
Smooth, Striated, Stiffener Ribs
Factory or Jobsite Roll-formed
Installing The 300 DL
At 3" tall, there is only one standard way to install this panel. A double locked seam is bent 180° to ensure maximum wind uplift resistant and weathertightness. Although the panel is capable of being only single-locked, we strongly encourage at double locked seam (DL).
The system features a 3 inch tall vertical rib standing seam panel that is seamed on the roof after installation. The panels are held to the substrate using 6 inch long, 20 gauge clips that allow for a full 2.5 inches of thermal movement.
Retrofit Roof Installation Over an Existing Metal Roof
300 DL panels have no end laps because they are manufactured right onto the roof in lengths up to 250 feet using one of our Archzilla® jobsite production monster trucks.
JSM 300 DL Product Specifications
JSM 300 DL panels were designed to offer maximum weathertightness in low slope conditions. There are millions of square feet of warehouse that JSM 300 DL is ideal for.
Our JSM 300 is the perfect fit for low slope, re-roofing. It offers relief in the way of eliminated endlaps and simplified, effective curb details. Learn more about how the the 300 DL can be used as a metal reroofing system.
JSM 300 DL CSI Guide Specifications
JSM 300 DL Product Data Sheet
UL Information
Product Installation Details
Eave with Standard Gutter
Clip Fastening Over Insulation
Isometric at Eave
Standard Eave
Eave with 7" Box Gutter
Isometric at Sloped to Fascia Transition
Roof to Fascia Transition
Hip/Ridge Detail
Headwall Detail